OPEN EDUCATIONAL RESOURCES

UPA PERPUSTAKAAN UNEJ | NPP. 3509212D1000001

  • Home
  • Admin
  • Select Language :
    Arabic Bengali Brazilian Portuguese English Espanol German Indonesian Japanese Malay Persian Russian Thai Turkish Urdu

Search by :

ALL Author Subject ISBN/ISSN Advanced Search

Last search:

{{tmpObj[k].text}}
No image available for this title
Bookmark Share

A New Forced Convection Heat Transfer Correlation for 2D Enclosures

Rincón-Casado, Alejandro - Personal Name; de la Flor, Francisco José Sánchez - Personal Name;

https://mts.intechopen.com/articles/show/title/a-new-forced-convection-heat-transfer-correlation-for-2d-enclosuresThis work presents a new parametric correlation for 2D enclosures with forced convection obtained from CFD simulation. The convective heat transfer coefficient of walls for enclosures depends on the geometry of the enclosure and the inlet and outlet openings, the velocity and the air to wall temperature difference. However, current correlations not dependent on the above parameters, especially the position of the inlet and outlet, or the temperature difference between the walls. In this work a new correlation of the average Nusselt number for each wall of the enclosure has been developed as a function of geometrical, hydrodynamic and thermal variables. These correlations have been obtained running a set of CFD simulations of a 3 m high sample enclosure with an inlet and outlet located at opposite walls. The varying parameters were: a) the aspect-ratio of the enclosure (L/H = 0.5 to 2), b) the size of the inlet and outlet (0.05 m to 2 m), c) the inlet and outlet relative height (0 m to 3 m high), and d) the Reynolds number (Rein = 103 to 105). Furthermore, a parametric analysis has been performed changing the temperature boundary conditions at the internal wall and founds a novel correlation function that relates different temperatures at each wall. A specifically developed numerical model based on the SIMPLER algorithm is used for the solution of the Navier-Stokes equations. The realisable turbulence k-ε model, and an enhanced wall-function treatment have been used. The heat transfer rate results obtained are expressed through dimensionless correlation-equations. All developed correlations have been compared with CFD simulations test cases obtaining a R2 = 0.98. This new correlation function could be used in building energy models to enhance accuracy of HVAC demands calculation and estimate the thermal load.https://creativecommons.org/licenses/by/3.0/en


Availability

No copy data

Detail Information
Series Title
-
Call Number
-
Publisher
: IntechOpen,., 2022-10-26.
Collation
-
Language
English
ISBN/ISSN
-
Classification
-
Content Type
-
Media Type
-
Carrier Type
-
Edition
-
Subject(s)
Chapter, Part Of Book
Specific Detail Info
-
Statement of Responsibility
-
Other version/related

No other version available

File Attachment
No Data
Comments

You must be logged in to post a comment

OPEN EDUCATIONAL RESOURCES

Search

start it by typing one or more keywords for title, author or subject


Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search
Where do you want to share?