OPEN EDUCATIONAL RESOURCES

UPA PERPUSTAKAAN UNEJ | NPP. 3509212D1000001

  • Home
  • Admin
  • Select Language :
    Arabic Bengali Brazilian Portuguese English Espanol German Indonesian Japanese Malay Persian Russian Thai Turkish Urdu

Search by :

ALL Author Subject ISBN/ISSN Advanced Search

Last search:

{{tmpObj[k].text}}
Image of Antibody Repertoire and Graft Outcome Following Solid Organ Transplantation
Bookmark Share

Text

Antibody Repertoire and Graft Outcome Following Solid Organ Transplantation


The first real major breakthrough that laid the basis of HLA antibody detection in the field of solid organ transplantation, came with the introduction of the complement dependent cytotoxicity (CDC) test in 1964 by Terasaki and McClelland. Since then, methods for antibody detection have evolved remarkably from conventional cell-based assays to the current advanced solid phase systems on the Luminex platform, with increasing degree of sensitivity and specificity. The latter have been indispensable for more accurate identification of donor specific HLA antibodies in broadly reactive allo antisera, and to guide donor selection and kidney paired exchange programs through virtual crossmatching, in addition to serving as excellent tools for initiating pre-transplant desensitization and post- transplant antibody monitoring. Consensus is evolving on the optimal routine employment of these methods in donor selection strategies along with an understanding of the clinical relevance of antibodies detected by each of them. The immunoassays based on the Luminex platform and flow cytometric beads are however unable to discriminate complement fixing from non-complement fixing HLA antibodies. This is important because the former are considered clinically more pertinent in the peri-transplant period. The C1q assay which is a modification of the solid phase assay based on Luminex single antigen beads, which can be used effectively to monitor high dose IVIG desensitization is essentially a surrogate complement fixing assay, retaining the exquisite sensitivity and specificity of the Luminex platform. Currently, information obtained from these assays is preliminary and much needs to be done to standardize technologies and set a consensus ‘MFI cut off’ for antibody positivity. Besides the overriding influence of anti-HLA antibodies on overall solid organ graft survival, immune response to non-HLA antigens has become a topic of substantial interest in recent years. An ever expanding list of non-HLA antigens has been implicated in graft rejection for various organs, of which the most noted are the Major Histocompatibility Complex class I chain-related molecule A (MICA), Vimentin, Myosin, Angiotensin II type 1 receptor (AT1R), Tubulin and Collagen. MICA is one of the most polymorphic and extensively studied non-HLA antigenic targets especially in renal transplantation. Although there are clear indications of MICA antibodies being associated with adverse graft outcome, to date a definitive consensus on this relationship has not been agreed. Because MICA molecules are not expressed constitutively on immunocompetent cells such as T and B lymphocytes, it is of utmost importance to address the impact of MICA donor specific antibodies (DSA) as compared to those that are non- donor specific (NDSA) on graft outcome. The soluble isoform of MICA molecule (sMICA) that is derived from the proteolytic shedding of membrane bound molecules has the potential to engage the NK-cell activating receptor NKG2D and down-regulate its expression. Consequent to the interaction of NKG2D by sMICA, the receptor ligand complex is endocytosed and degraded and thus suppresses NKG2D mediated lysis of the target by NK cells. Thus interaction between NKG2D and sMICA leads to expansion of immunosuppressive/anergic T cells thereby resulting in suppression of NKG2D mediated host innate immunity. These concept support the possible involvement of an immunosuppressive role for sMICA during allotransplantation as shown recently for heart transplantation. This research topic focuses on the clinical utility of investigating the complete antibody repertoire in solid organ transplantation.


Availability

No copy data

Detail Information
Series Title
-
Call Number
-
Publisher
: ., 2017
Collation
-
Language
ISBN/ISSN
9782889452415
Classification
NONE
Content Type
text
Media Type
computer
Carrier Type
online resource
Edition
-
Subject(s)
-
Specific Detail Info
-
Statement of Responsibility
Ajay Kumar Baranwal
Other Information
Cataloger
Siti
Source
-
Validator
-
Digital Object Identifier (DOI)
10.3389/978-2-88945-241-5
Journal Volume
-
Journal Issue
-
Subtitle
-
Parallel Title
-
Other version/related

No other version available

File Attachment
  • Antibody Repertoire and Graft Outcome Following Solid Organ Transplantation
Comments

You must be logged in to post a comment

OPEN EDUCATIONAL RESOURCES

Search

start it by typing one or more keywords for title, author or subject


Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search
Where do you want to share?